IP Indian Journal of Orthodontics and Dentofacial Research

Print ISSN: 2581-9356

Online ISSN: 2581-9364

CODEN : IIJOCV

IP Indian Journal of Orthodontics and Dentofacial Research (IJODR) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the more...

  • Article highlights
  • Article tables
  • Article images

Article statistics

Viewed: 44

PDF Downloaded: 15


Get Permission Selvaraj, Rajendran, Sumithra Devi, Jeevagan, and Rami Reddy: Assessing biomechanical aging of aligners produced by different thermoformed machine using 3d scanner -An invivo study


Introduction

Orthodontic aligners have become a popular treatment modality due to their aesthetic appeal and convenience. While clear aligner therapy seems very easy to use, any kind of aligner system needs to go through a rigorous laboratory process to get the desired results. However, the longevity and effectiveness of aligners can be influenced by various factors, including the thermoforming process used for their fabrication. 1 This in vivo study aims to assess the biomechanical aging of aligners produced by different thermoformed machines using a 3D scanner. By comparing aligners produced by different thermoforming machines, this research seeks to provide insights into the impact of manufacturing processes on aligner performance and durability.

The findings of this in vivo study will provide valuable insights into the biomechanical aging of aligners produced by different thermoformed machines. By elucidating the impact of manufacturing processes on aligner performance, this research has the potential to inform clinical practice and guide advancements in aligner fabrication technology.

Thermoforming units can be used to make counter bites, sports mouthguards, bleaching trays, and transparent aligners, among other thing. 2The Ministar thermoforming machine and the Druformat thermoforming machines were taken for this study, both of which are readily available on the market. According to the manufacturers, the efficiency of the machines was quite impressive.

Aim

The aim of this study is to compare the biomechanical aging behaviours like Surface wear profile, dimensional changes of orthodontic aligners made by various thermoformed machines over different time periods from day 1 to day 10 in intraoral environment.

Materials and Methods

The sample size was determined using G power software, which showed that the sample size of six patients divided into four groups had a 95% power of statistical testing. Five patients, three women(mean age ± SD 26.0 ± 10.2 years) and two men(mean age ± SD 26.0 ± 9.0 years) per group made up the study sample. Patients who reported to Adhiparasakthi Dental College and Hospital provided study samples. Each patient received an explanation of the study protocol, which included the fact that they were not part of the active phase of treatment, that the patients who volunteered were part of the study, and that their informed consent was obtained.

Inclusion criteria

Subjects over the age of 18, with natural dentition except for the third molars, good oral hygiene, and no signs of periodontal disease. Mild crowding - 0.5-3mm ,Class I and II molar relationship less than 30° rotation of tooth Subjects who are in good health and have no medical or psychological issues.

Exclusion criteria

Medications used to treat neurological diseases(such as anti depressants) Patients suffering from orofacial or temporomandibular pain, temporomandibular disorder,Patient who are suffering from bruxism Symptoms of active carious lesions.Patient who has undergone previous orthodontic care History of polyethylene terephthalate glycol - modified(PET -G) polyurethane, polyether resin allergy.

The study sample was chosen based on inclusion and exclusion criteria, and random allocation was done without bias. To avoid operational errors and discrepancies, all procedures and lab-related operations are performed by the principal investigator and a well-trained assistant.

Study materials

The aligners used in this study were made of polyethylene terephthalate glycol copolyester(PET-G) Duran® SCHEU-DENTAL transparent aligner material,(1.0-mm thick) and were all produced with a thermoforming machine (Ministar of Scheu Dental, Iserlohn, Germany, Drufomat thermoforming machine) using the vacuum thermoforming process at a temperature of 220 °C and 2.5 bar(36 psi) pressure. The models used as molds for thermoforming the aligners were created using a 3D printing machine (UNIZ NBEE Desktop 3D Printer). Each aligner was manually cut and trimmed along the gingival margins, and the edges were manually refined to ensure the best comfort for the patients and to avoid negative influences that could arise from an automatic cutting process.

The aligners were produced by using Ministar(Group A) (Figure 1) and Druformat (Group B) (Figure 2) thermoforming machine. Followed by the fabrication process the aligners were scanned initially using ATOMS industrial scanner(Figure 3) at day 0(T0). Then aligners were delivered to both the groups and instructed wear the aligner for 22 hours maximum. 1 The patients of both groups were recalled at day 10 and the retrieved aligners were scanned. The Surface profile changes of orthodontic aligners of both the groups were analysed using Geomagic control X software(Figure 4) and values were tabulated and subjected to statistical analysis(Figure 5).Thermoforming machine (Figure 1, Figure 2).

Figure 1

Ministar thermoforming machine

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/6b36fff2-f684-4e97-90d6-6c79f5586e03/image/fd2b61fc-1fe9-4b18-9a15-854c436db6eb-uimage.png

Figure 2

Drufomat thermoforming machine

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/6b36fff2-f684-4e97-90d6-6c79f5586e03/image/bccf2d3e-e245-447e-b065-47c7a7955e9d-uimage.png

Figure 3

Polyethylene terephthalate glycol copolyester (PET –G) Duran® Scheu-Dental transparent material (0.75 mm and 1.00 mm)

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/6b36fff2-f684-4e97-90d6-6c79f5586e03/image/5b9f8bc2-2cc7-4290-96b5-cd41ea51bb1e-uimage.png

Figure 4

Atoms compact scan portable 3D Scanner and geomagic control X metrology software

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/6b36fff2-f684-4e97-90d6-6c79f5586e03/image/8327854b-4fbb-488a-a86a-09b5fd5571eb-uimage.png

Figure 5

Analysed model from geomagic control X metrology software

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/6b36fff2-f684-4e97-90d6-6c79f5586e03/image/18f7f90f-e96a-434c-a96f-2891eac77354-uimage.png

Study design

Each patient was individually scanned using an intraoral scanner(densply sirona) by principal investigator. Following the scanning, all digital impressions were imported into Maestro 3D Dental Studio software, where a virtual three-dimensional model was created.

(https://www.maestro3d/dental.studio.aspx?id=en-US).

After creating a virtual model, the next step is to create a 3D printing file, which is known as slicing. After the software(https://www.uniz.com/software) has finished slicing the model, it has sent it directly to the printer. UNIZ NBEE Desktop 3D Printer used to print the virtual models.

The thermoplastic sheet was then inserted into the tension ring of the thermoforming machine(Ministar of Scheu Dental, Iserlohn, Germany), and the 3D-printed model was placed on the Ministar platform. For the thermoforming process, the temperature was set to 220 degrees Celsius and the pressure to 2.5 bar (36 psi) pressure.The thermoformed untrimmed Passive aligner sheets were removed from the Ministar.

The Duran® sheets were then placed in the Drufomat thermoforming machine, the temperature was set to 220 degrees Celsius, and the pressure was set to 2.5 bar(36 psi). After the retrival of untrimmed aligner sheets from the machine, the final step is to finishing.low-speed grinding tools used to perform detailed trimming of the aligners. It is vital to avoid creating any sharp or jagged edges that could irritate the patient's mouth or damage the surrounding tissues.

Once trimmed, their internal surface of the Passive aligner(P aligner) is spray coated with a CAD/CAM spray(Yeti Dental, GmbH, Engen, Germany) white translucent matter to visualize the aligner from the resin model in 3D scanner. 3 Prior to insertion,(T0) P aligner the was individually scanned using a ATOS Compact Scan Portable 3D Scanner with the resin model, followed by the P aligner without the resin model, to measure the marginal gap between the aligner and the resin model. After scanning, the models were, thoroughly cleaned and cold sterilized before inserting the patient. The insertion of the P aligners was overseen by a principal investigator. Proper instruction and guidance were given to the patient regarding aligner wear time and its maintenance. With regard to the same a designed Performa was made and patient was instructed to make an entry regarding their wear time of aligner.

Results

Table 1

Intra-group comparisons of group A

Tooth

Time

Mean

SD

Mean difference

95% Confidence Interval of the Difference

P value

LCL

UCL

Incisor

Day 0

0.0921

0.0065

0.0234

-0.1165

0.0698

0.524 NS

Day 10

0.1155

0.0754

Canine

Day 0

0.0557

0.0134

0.0104

-0.0275

0.0068

0.168 NS

Day 10

0.0661

0.0092

Molar

Day 0

0.0522

0.0155

0.0191

-0.0666

0.0284

0.326 NS

Day 10

0.0713

0.0402

[i] Statistical analysis: paired t test. S: statistically significant if P<0.05.

Graph 1

Intra-group comparisons of group A

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/6b36fff2-f684-4e97-90d6-6c79f5586e03/image/f36899cd-25ab-4c12-a3c6-41bfc474d958-ua.png

Table 2

Intra-group comparisons of group B.

Tooth

Time

Mean

SD

Mean difference

95% Confidence Interval of the Difference

P value

LCL

UCL

Incisor

Day 0

0.0065

0.0034

0.0182

-0.0400

0.0036

0.082 NS

Day 10

0.0247

0.0146

Canine

Day 0

0.0025

0.0012

0.0094

-0.0170

-0.0017

0.027 S

Day 10

0.0119

0.0068

Molar

Day 0

0.0148

0.002

0.0039

-0.0112

0.0032

0.199 NS

Day 10

0.0187

0.0047

[i] Statistical Analysis: Paired t test. S: Statistically significant if P<0.05.

Graph 2

Intra-group comparisons of group B

https://typeset-prod-media-server.s3.amazonaws.com/article_uploads/6b36fff2-f684-4e97-90d6-6c79f5586e03/image/229fa625-0f44-40fa-b029-f9da8dfbaaac-uimage.png

Table 3

Inter-group comparison between group A and group B.

Tooth

Time

Group A

Group B

Mean difference

P value

Mean

SD

Mean

SD

Incisor

Day 0

0.0921

0.0065

0.0065

0.0034

0.0856

0.000 S

Day 10

0.1155

0.0754

0.0247

0.0146

0.0908

0.029 S

Canine

Day 0

0.0557

0.0134

0.0025

0.0012

0.0532

0.000 S

Day 10

0.0661

0.0092

0.0119

0.0068

0.0542

0.000 S

Molar

Day 0

0.0522

0.0155

0.0148

0.002

0.0374

0.001 S

Day 10

0.0713

0.0402

0.0187

0.0047

0.0526

0.020 S

[i] Statistical analysis: independent sample t test. S: statistically significant if P<0.05.

Discussion

The present clinical prospective study was to investigate and evaluate the efficacy of aligner manufactured by different thermoforming equipment’s with regard to aging changes. The recent studies concentrating only on the analysis of three-dimensional(3D) printed aligners, But the most popular technique for creating aligners is thermoforming so the fit of thermoformed aligners is determined by the manufacturing procedures, as well as the elastic modulus of the materials utilized. 4 With regard to the modification of nominal aligner thickness by thermoforming procedures which could affect the orthodontic forces transmitted. 5

In this study we have used Duran thermoforming sheets for this investigation. Studies also proven that Statistically, Duran sheets(Figure 3) provide best efficacy in aligner fabrication. These sheets of Duran are composed of PETG, which is a transparent, amorphous copolymer of polyethylene terephthalate(PET) that has good optical, fatigue, mechanical, and dimensional stability characteristics. 6 It is distinguished by having good manufacturability and minimal hygroscopic Changes. 7 When Kwon et al., evaluated the force delivery characteristics of thermoplastic orthodontic materials, they discovered that the forces provided by thin materials of the same brand were higher than those delivered by thick materials. 3 So, to assess the aging of the thicker material have been selected for this study. The thermoplastic materials used to fabricate aligners are structurally made of partially crystalline or amorphous polymers, which allow visible light to pass through and give a transparent appearance. 8 Owing to the transparent nature of the p aligners utilized in this investigation, an opacifying liquid had to be applied to each P aligner.

An Opacifying liquid had been used to increase the scanning accuracy. It creating an opaque surface that allows light to bounce off the object uniformly. Contrasting spray thickness was measured by Nickolas Koeniget al., in 2022; it ranged from 0.01899 mm to 0.0803 mm. It is evident that the spray affected the readings even if the study was unable to pinpoint the exact effect of the spray on aligner thickness. 9 When compared side by side, the average positive deviations had greater magnitudes of values than the average negative deviations, 10 According to Marian C. McCarty et al's., 2020 report, this discrepancy could be caused by the aligners' residual supports and the application of opacifying spray. Despite the possibility for positive biases from these sources, the aligners were generally found to be within a tolerance range that is considered clinically appropriate. 11

The thermoforming process reduces the thickness of the sheet, creating aligners from 0.125 mm up to 0.30 mm thinner than the original thermoforming sheet thickness. The reduction of thickness is not uniform and varies at different locations. 12 Thickness as well volumetric changes of the aligner will be changed due to its hygroscopic nature of the polymers. These properties of the aligners will affect the effective tooth movement and ultimately lowers standards of the aligner treatment. Aligners have been used in clinical applications where stepped teeth have been moved by approximately 0.25 to 0.33 mm. Here, it was shown that activation of the device every 2 weeks was effective for orthodontic tooth movement. 13 Prolonged use of the aligner will lose its integrity ultimately lowers the effective tooth movements. 14 In this study the Passive Aligners were fabricated using with two different thermoforming machine and biomechanical aging of aligners were analysed before and after intraoral exposure.

Geomagic software used to assess the volumetric changes after using ATOMS industrial scanner. Geomagic software packages consistently showed maximum accuracy in measuring the amount of tooth movement in the maxillary arch compared to the reference standard. 15

Both the thermoforming machines can used to fabricate aligners that are equally good in terms of thickness considering the manufacturing recommendation. However, Aligner fabricated using Ministar thermoforming machine(Group A) with 1 mm thickness sheets shows that Mild changes thickness throughout the aligners in incisor and canine and molar regions (Table 1) and Druformat(Table 2) with shows uniformly distributed(group B) thickness in incisor, canine and molar region between intra group comparison group(Table 3) shows mild changes after intraoral exposure but the values within clinical tolerance level.

Conclusion

The Passive Aligners fabricated using with two different thermoforming machine and the total dimensional accuracy at each of the teeth was within the clinical tolerances. The overall deviations, however, might not always represent location-specific deviations that could have an impact on clinical utility. The overall changes are within the clinical tolerance level. In terms of Biomechanical aging, these values are suggesting change of an aligner, within 10 days, prolonged use of aligner will lose its integrity, so that, it will not produce efficient tooth movement.

The information’s about the thermoforming process could be useful to clinicians, who have the intention to establish their staging procedure for clear aligner therapy with good efficiency and without overtaxing the periodontal ligament.

Limitation

This study was done in passive aligners with normal occlusion, to validate this finding the study has to be done in larger population with severe malocclusion by varying thickness of sheets.

Source of Funding

None.

Conflict of Interest

None.

References

1 

H Ryokawa Y Miyazaki A Fujishima T Miyazaki K Maki The mechanical properties of dental thermoplastic materials in a simulated intraoral environment. Orthod WavesOrthod Waves20066526472

2 

T Weir Clear aligners in orthodontic treatmentAust Dent J201762S15862

3 

MB Yashodhan A Alwafi X Liu J Andrews B Ludwig YB Aditi Advances in orthodontic clear aligner materialsBioact Mate202222384403

4 

I Parisay M Boskabady M Abdollahi M Sufiani Treatment of severe rotations of maxillary central incisors with whip appliance: Report of three casesDent Res J (Isfahan)20141111339

5 

AI Linjawia M Amal Abushal Adaptational changes in clear aligner fit with time: A scanning electron microscopy analysisAngle Orthod9222205

6 

A Edelmann JD English SJ Chen FK Kasper Analysis of the thickness of 3-dimensional-printed orthodontic alignerAm J Orthod Dentofacial Orthop20201585918

7 

M Palone M Longo N Arveda Mario Palone Micro-computed tomography evaluation of general trends in aligner thickness and gap width after thermoforming procedures involving six commercial clear aligners: An in vitro studyKorean J Orthod202151213541

8 

F Tamburrino V D'Antò R Bucci G Alessandri-Bonetti S Barone Francesco Tamburrino Properties of Thermoplastic Polymers for Aligner Manufacturing: In Vitro StudyDent J (Basel)20208247

9 

JH Ryu JS Kwon HB Jiang JY Cha KM Kim Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic alignersKorean J Orthod201848531625

10 

R Zhao L Mei H Long F Jian W Lai Aust Orthod J Changing clear aligners every 10 days or 14 days A randomised controlled trial202339112

11 

N Koenig JY Choi J Mccray A Hayes P Schneider KB Kim Comparison of dimensional accuracy between direct-printed and thermoformed alignersKorean J Orthod202252424957

12 

MC McCarty SJ Chen SJ Chen JD English F Kasper Effect of print orientation and duration of ultraviolet curing on the dimensional accuracy of a 3-dimensionally printed orthodontic clear aligner designAm J Orthod Dentofacial Orthop2020158688997

13 

N Koenig JY Choi J McCray A Hayes P Schneider KB Kim Comparison of dimensional accuracy between direct-printed and thermoformed alignersKorean J Orthod202252424957

14 

JH Ryu JS Kwon HBo Jiang JY Cha KM Kim Effects of thermoforming on the physical and mechanical properties of thermoplastic materials for transparent orthodontic alignersKorean J Orthod201848531625

15 

SM Adel NR Vaid N El-Harouni H Kassem AR Zaher Compare and Geomagic software packages consistently showed maximum accuracy in measuring the amount of tooth movement in the maxillary arch compared to the reference standardBMC Oral Health 2022221103



jats-html.xsl


This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

Article type

Original Article


Article page

250-255


Authors Details

Priyanka Selvaraj*, Ramya Rajendran, K.S. Sumithra Devi, Sruthi Jeevagan, Mora Sathi Rami Reddy


Article History

Received : 17-07-2024

Accepted : 10-09-2024


Article Metrics


View Article As

 


Downlaod Files