IP Indian Journal of Orthodontics and Dentofacial Research

Print ISSN: 2581-9356

Online ISSN: 2581-9364

CODEN : IIJOCV

IP Indian Journal of Orthodontics and Dentofacial Research (IJODR) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the more...

Article type

Original Article


Article page

154-159


Authors Details

Satyabrata Das, Goutham N., Nitin R. Khargekar, Arora Chiragkumar K.


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1619

PDF Downloaded: 586


Comparative assessment of bone stress associated with miniplates and mini-implants used for orthodontic anchorage: A finite element study


Original Article

Author Details : Satyabrata Das, Goutham N., Nitin R. Khargekar, Arora Chiragkumar K.

Volume : 2, Issue : 4, Year : 2016

Article Page : 154-159


Suggest article by email

Get Permission

Abstract

Objective: To assess and compare bone stress associated with various miniplates and mini-implant systems by using finite element analysis.
Materials and Methods: Bone stress associated with various miniplate and mini-implant systems were compared and assessed by using finite element analysis and taking into account a number of variables, which play an important role in the success, and failure of such TAD systems.
Results: Peak von Mises stresses in cortical and cancellous bones for Miniplate Base Model are 18.43 MPa and 1.735 MPa respectively and for Mini-Implant Base Model are 1.621 Mpa and 0.2645 MPa respectively.
Conclusion: Bone stress due to miniplate is more compared to mini-implant. Bone stress decreases with increased cortical thickness, increases with increased force magnitude. Highest bone stress is due to I-type followed by L-type, Y-type and T-type miniplate. Increased miniplate fixation screw length for miniplate or mini-implant length doesn't have significant effect on bone stress. Bone stress decreases as mini-implant diameter increases.

Keywords: Miniplate, Mini-implant, Bone Stress, Finite Element Analysis


How to cite : Das S, Goutham N., Khargekar N R, Arora Chiragkumar K., Comparative assessment of bone stress associated with miniplates and mini-implants used for orthodontic anchorage: A finite element study. IP Indian J Orthod Dentofacial Res 2016;2(4):154-159

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.