IP Indian Journal of Orthodontics and Dentofacial Research

Print ISSN: 2581-9356

Online ISSN: 2581-9364

CODEN : IIJOCV

IP Indian Journal of Orthodontics and Dentofacial Research (IJODR) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the more...

Article type

Original Article


Article page

260-266


Authors Details

Ajit Kalia*, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 367

PDF Downloaded: 158


Esthetic nickel titanium wires– Do they deliver the same force?


Original Article

Author Details : Ajit Kalia*, Juhi Joshi, Mohammed Mandsaurwala, Sayali Bobade, Azmat Azha Khan

Volume : 8, Issue : 4, Year : 2022

Article Page : 260-266

https://doi.org/10.18231/j.ijodr.2022.045



Suggest article by email

Get Permission

Abstract

Objective: To test the difference in loading and unloading forces delivered by six coated nickel-titanium wires and their non-coated equivalents.
Materials and Methods: Commercially available six coated nickel-titanium wires and their non-coated equivalents of sizes 0.016-inch diameter round and 0.016 X 0.022-inch rectangular cross-section were procured. The wires were evaluated using a three-point bending test based on the method in ISO Standard 15841.
Results: No statistically significant differences in force values were found between coated and non-coated wires, listed by deflection in three-point bending, for these specific groups.
Statistical analysis was done using SPSS version 11.5 (Chicago, III). Analysis of variance was performed with Sheffe post hoc for the mean comparison among the measurements of each loading and unloading deflection for coated and non-coated wires. Student’s t-tests was performed for the mean comparisons between non coated and coated groups for each deflection.
Conclusion: There is no significant difference in load response between coated and non-coated nickel-titanium wires of the same size when subjected to the same deflection using a standard three-point bend test method.
 

Keywords: Coated Nickel­titanium wires, Non­coated Nickel­titanium wires, Three­ point bending test


How to cite : Kalia A, Joshi J, Mandsaurwala M, Bobade S, Khan A A, Esthetic nickel titanium wires– Do they deliver the same force?. IP Indian J Orthod Dentofacial Res 2022;8(4):260-266

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.