IP Indian Journal of Orthodontics and Dentofacial Research

Print ISSN: 2581-9356

Online ISSN: 2581-9364

CODEN : IIJOCV

IP Indian Journal of Orthodontics and Dentofacial Research (IJODR) open access, peer-reviewed quarterly journal publishing since 2015 and is published under the Khyati Education and Research Foundation (KERF), is registered as a non-profit society (under the society registration act, 1860), Government of India with the vision of various accredited vocational courses in healthcare, education, paramedical, yoga, publication, teaching and research activity, with the aim of faster and better dissemination of knowledge, we will be publishing the more...

Article type

Original Article


Article page

237-244


Authors Details

Rohan Jacob Sam*, Vaibhav Mishra, Ashish Yadav, Deepanshi Yadav, Divya Joshi, Kshetrimayum Martina


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 696

PDF Downloaded: 238


Effect of chlorhexidine mouth rinse in force decay of closed, short and long elastomeric chain - An in vitro study


Original Article

Author Details : Rohan Jacob Sam*, Vaibhav Mishra, Ashish Yadav, Deepanshi Yadav, Divya Joshi, Kshetrimayum Martina

Volume : 8, Issue : 4, Year : 2022

Article Page : 237-244

https://doi.org/10.18231/j.ijodr.2022.041



Suggest article by email

Get Permission

Abstract

Introduction: Elastomeric chain is one of the most commonly used orthodontic material, Evaluating the force transmission ability of elastomeric chains is essential so that orthodontists can estimate the actual force transferred to the dentition. The aim of this study was to assess effect of chlorhexidine mouth rinse on force decay of continuous, short and long elastomeric chain in chlorhexidine mouth wash.
Materials and Methods: The sample consisted three commercially available Orthodontic elastomeric chain (American Orthodontics, clear) such as continuous, short and long. These elastomeric chains were analysed with one experimental group and one control group. In control group all the three types of chain were dipped in distilled water for 30 second every day while in experimental group these elastomeric chains were dipped in mouth wash (Clohex Mouth Wash ADS) for 30 second every day. The result was tested by digital dynamometer and was statistically evaluated using ANOVA test.
Result: Continuous elastomeric chain showed least force decay in both experimental and control group throughout the study. In the inter group comparison there was significant difference of force decay between elastomeric chains with the control group and experimental group in the 3 week in both continuous and short elastomeric chain, experimental group showed more force decay.
Conclusion: Mouthwash does not accelerate force degradation of elastomeric chains which could clinically affect their effectiveness. However, the results could be variable in the presence of other biological factors in the oral environment and their interactions between oral microorganisms with the host.
 

Keywords: Elastomeric chains, Chlorhexidine Mouthwash, Artificial saliva, Force Decay


How to cite : Sam R J, Mishra V, Yadav A, Yadav D, Joshi D, Martina K, Effect of chlorhexidine mouth rinse in force decay of closed, short and long elastomeric chain - An in vitro study. IP Indian J Orthod Dentofacial Res 2022;8(4):237-244

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.